ArticleName
Substantiation of usage of Casdent gold alloy for manufacture of clasp dental prostheses
ArticleAuthors
Lebedenko I. Yu., Tagil’tsev D. I., Manin O. I., Parunov V. A.
ArticleAuthorsData
Tagil’tsev D. I., e-mail: tagiltsevy@mail.ru.
Abstract
The new domestic alloy named Casdent (Super LB) has been investigated in three directions: physical-mechanical properties, operating properties and biocompatibility. As a result of undertaken investigation, it was concluded that gold-based Casdent alloy is valid for usage in orthopedic stomatology for manufacturing clammer clasp dental prostheses in physical-mechanical properties, operating properties, workability and biocompatibility.
keywords
stomatology, clasp dental prostheses, clammers, gold-bearing alloy,manufacture of prostheses, biocompatibility, operating properties.
Language of full-text
russian
Full content